 Anaesthesia machine VETNAR 2200  
 

The machine VETNAR 2200 produced by our company has a modular design.
The basic breathing unit VETNAR 2200 Basic can be anytime completed with additional modules like unit for electronically controlled ventilation and vital function monitor (like ECG, breathing, Sa02 a CO2) as well.
We standardly produce a machine, where supporting gases O2 + N2O or O2 + air are used. Naturally, you can use O2 only. From the viewpoint of saving O2, it is more suitable to use N2O or air as well. It is also possible to use oxygen concentrator as oxygen source. Advantage of the machine is using of precision vaporizers outside of the breathing circuit. Isoflurane or/and Sevoflurane can be used. Because of unique system DIF (Direct Inspiration Flow) you can work on semi-closed system already from 2-3 kg of patient weight. Open system works from 0,1 kg of patient weight. Electronically controlled ventilation is possible to use also for resuscitation of a patient.


 
 
Versatile anaesthesia apparatus small animals from 0.1 to 100 kg

Semi-closed and open circuit for spontaneous breathing

Hi-quality silicone breathing circuits and bags

Electronically controlled ventilation for both semi-close and open system

O2 + N2O or O2 + air supporting gasses

CO2 absorber

Build-in monitoring of breathing, heart activity, SaO2 and CO2

Active pollution scavenging system for transport exhaust gasses

Two flow-meters
O2 and N2O or O2 and air


Small stable trolley on the wheels with holder for up to two 10 l gas cylinders

Minimal size requirement
Dimension 520 x 520 x 1330 mm
 
 

Precision vaporizer outside of breathing circuit

Possibility to mount two vaporizers

Safety relief valve

O2 bypass valve


 
 


 
Possibility to use it as resuscitation machine with monitoring

Economic in consumption of O2 and anesthetic

 

     Download the handbill:   

               Veterinary Vital Function Monitor

                                                               Back

 

In the course of operations and directly after operations of small animals it is very good to provide for the monitoring of the patient's vital functions both from the standpoint of keeping the operator calm and providing perfect care for the patient.
Build-in monitor is possible to use during surgery but also of course alone without anesthesia.

 

 
 

 
Monitoring of heart activity
 

Monitoring of breathing
 

Monitoring of SaO2
 
Monitoring of CO2 in the breathing circuit
 
Acoustic and optical indication
 
Acoustic alarm of minimal value
 
Acoustic alarm of cardiac arrest and apnoe
 
Easy to connect to the patient
 
Easy to use
 
Supplying with safe voltage by means of adapter 230V/12V
 

Small dimensions, Cost efficient

 
 